Home / About Us / Products / Support / Contact

Products  >  Networking & ADSL > Network Switches

Advantech EKI-5726I-AE 16 Port Unmanaged Switch
Dove Code: AQ7203 |
Manufacturer: EKI-5726I-AE

Overview

The EKI-5726/I is the world’s first convergence switch for process control and IT networking management. This series uses Modbus/TCP to communicate with the SCADA software and SNMP to communicate with the NMS (Networking Management System) at the same time, thereby allowing full read control over the devices either for control engineers or for IT. The devices come with the Port-based QoS for deterministic data transmission allows the priority ports to prioritize the traffic coming over those ports and delay the less immediately necessary data over the remaining ports. The EKI-5726/I switch uses the highest quality components, to enable the range to operate in temperatures of between -40 and 75°C along with EMS Level 3 protection to repel electromagnetic interface for industrial resistance.

Warranty

60 Month Warranty

Features

  • Communicates with SCADA software via Modbus/TCP
  • Communicates with NMS (Networking management system) via SNMP
  • Port-based QoS for deterministic data transmission
  • -40~75°C operating temperature range (EKI-5726I only)
  • 12 ~48 V DC (8.4~52.8 V DC ) wide-range power input
  • EMS level 3 protection for extreme outdoor environments
  • IEEE 802.3az Energy Efficient Ethernet (EEE)
  • Supports redundant 12~48 V DC power input and P-Fail relay
  • Loop detection

Specifications

Product CategoryUnmanagedYes
Communication (XX)IEEE StandardIEEE 802.3, 802.3u, 802.3x, 802.1p, 802.3az, 802.3ab
Port ConfigurationEthernet Port Description16x 10/100/1000Base-T(X)
Ethernet Transmission Distance100m
Switch PropertiesMAC Table Size8K
Packet Buffer Size4.1M bit
Switch Fabric Speed32 Gbps
Jumbo Frame9,216 bytes
MechanismIP RatingIP30
EnclosureMetal
Mounting (X)DIN-rail, Wall
EnvironmentOperating Temperature (X)-40 ~ 75°C (-40 ~ 167°F)
Storage Temperature (X)-40 ~ 85°C (-40 ~ 185°F)
Relative Humidity (Non-condensing)10 ~ 95%
MTBFTime2,788,343 hours
MethodTelcordia(Relax), GB
Power Requirement (X)Operating Voltage12 ~ 48 VDC
Operating Current0.36A @ 24V
Power ConsumptionMax. 8W
Connectors6-pin removable screw terminal ((power & relay)
Reverse PolarityPresent
CertificationEMI(X) EN 55011/ EN 55022 Class A, EN 61000-6-4, FCC Part 15 Subpart B Class A
ShockIEC 60068-2-27
FreefallIEC 60068-2-32
VibrationIEC 60068-2-6
GeneralDimensions (mm)74 (w) x 120 (h) x 84 (d)
Weight800g
See full manufacturer specifications