Advantech EKI-5726I-AE 16 Port Unmanaged Switch
Dove Code:
AQ7203 |
Manufacturer:
EKI-5726I-AE
Overview
The EKI-5726/I is the world’s first convergence switch for process control and IT networking management. This series uses Modbus/TCP to communicate with the SCADA software and SNMP to communicate with the NMS (Networking Management System) at the same time, thereby allowing full read control over the devices either for control engineers or for IT. The devices come with the Port-based QoS for deterministic data transmission allows the priority ports to prioritize the traffic coming over those ports and delay the less immediately necessary data over the remaining ports. The EKI-5726/I switch uses the highest quality components, to enable the range to operate in temperatures of between -40 and 75°C along with EMS Level 3 protection to repel electromagnetic interface for industrial resistance.
Warranty
60 Month Warranty
Features
- Communicates with SCADA software via Modbus/TCP
- Communicates with NMS (Networking management system) via SNMP
- Port-based QoS for deterministic data transmission
- -40~75°C operating temperature range (EKI-5726I only)
- 12 ~48 V DC (8.4~52.8 V DC ) wide-range power input
- EMS level 3 protection for extreme outdoor environments
- IEEE 802.3az Energy Efficient Ethernet (EEE)
- Supports redundant 12~48 V DC power input and P-Fail relay
- Loop detection
Specifications
Product Category | Unmanaged | Yes |
---|
Communication (XX) | IEEE Standard | IEEE 802.3, 802.3u, 802.3x, 802.1p, 802.3az, 802.3ab |
---|
Port Configuration | Ethernet Port Description | 16x 10/100/1000Base-T(X) |
---|
| Ethernet Transmission Distance | 100m |
---|
Switch Properties | MAC Table Size | 8K |
---|
| Packet Buffer Size | 4.1M bit |
---|
| Switch Fabric Speed | 32 Gbps |
---|
| Jumbo Frame | 9,216 bytes |
---|
Mechanism | IP Rating | IP30 |
---|
| Enclosure | Metal |
---|
| Mounting (X) | DIN-rail, Wall |
---|
Environment | Operating Temperature (X) | -40 ~ 75°C (-40 ~ 167°F) |
---|
| Storage Temperature (X) | -40 ~ 85°C (-40 ~ 185°F) |
---|
| Relative Humidity (Non-condensing) | 10 ~ 95% |
---|
MTBF | Time | 2,788,343 hours |
---|
| Method | Telcordia(Relax), GB |
---|
Power Requirement (X) | Operating Voltage | 12 ~ 48 VDC |
---|
| Operating Current | 0.36A @ 24V |
---|
| Power Consumption | Max. 8W |
---|
| Connectors | 6-pin removable screw terminal ((power & relay) |
---|
| Reverse Polarity | Present |
---|
Certification | EMI | (X) EN 55011/ EN 55022 Class A, EN 61000-6-4, FCC Part 15 Subpart B Class A |
---|
| Shock | IEC 60068-2-27 |
---|
| Freefall | IEC 60068-2-32 |
---|
| Vibration | IEC 60068-2-6 |
---|
General | Dimensions (mm) | 74 (w) x 120 (h) x 84 (d) |
---|
| Weight | 800g |
---|
See full manufacturer specifications