| Rating | 8000VA/8000W |
---|
Input | Operating Frequency, Nominal | 60 Hz (Factory Default is 50 Hz ) |
---|
| Factory Default Voltage | 230 VAC |
---|
| User Configurable Voltage | 200/208/220/230/240 VAC |
---|
| Operating Voltage Range without Battery Operation | 176 to 288 VAC (100 to 176 VAC with power derating) |
---|
| Maximum Allowable Voltage | 288 VAC |
---|
| Input Frequency without Battery Operation | 40 to 70 Hz |
---|
Output | AC-AC Efficiency | 94.5% |
---|
| Factory Default Voltage | 230VAC |
---|
| Frequency | 50 Hz or 60 Hz, Nominal |
---|
| Waveform | Pure Sinewave |
---|
| Output Power Connection | Output Terminal Block |
---|
| Main Mode Overload | >150% minimum 200 ms, 125 – 150% for 60 seconds; 105 – 125% for 5 minutes; ≤ 105% continuous |
---|
Internal Battery | Charger Current | 2.25 A (default), maximum 8 A |
---|
| Type | Valve-regulated, non-spillable, lead acid |
---|
| Quantity x V x Rating | 2 x 8 x 12V x 9.0 AH |
---|
| Internal Battery Backup Time (Approximate) | 10% Load Capacity: 75 mins 20% Load Capacity: 33.5 mins 30% Load Capacity: 19.5 mins 40% Load Capacity: 13 mins 50% Load Capacity: 9.5 mins 60% Load Capacity: 7.5 mins 70% Load Capacity: 6 mins 80% Load Capacity: 4.5 mins 90% Load Capacity: 4 mins 100% Load Capacity: 3.5 mins |
---|
Bypass Protection Limits | Upper-limit selections | + 10%, + 15%, + 20%; default + 10%. |
---|
| Lower-limit selections | - 10%, - 15%, - 20%; default - 15% |
---|
| Disable-bypass operation | When the input frequency prevents synchronous operation |
---|
General | Operating Temperature, °C | Full power up to 40 ºC (up to 50 ºC with derating) |
---|
| Storage Temperature, °C | - 15 to + 40 |
---|
| Relative Humidity | 0 – 95% non-condensing |
---|
| Operating Elevation | Up to 3,000 m (9,842.5 ft) at 25°C (77°F) without derating |
---|
| Audible Noise | <55 dBA, at 1 meter from the front, <50 dBA, at 1 meter from rear or sides |
---|
| Safety | IEC62040-1:2008 version, GS mark |
---|
| EMI/EMC/C-Tick EMC | IEC/EN/AS 62040-2 2nd Ed (Cat 2 ) |
---|
| ESD | IEC/EN EN61000-4-2, Level 4, Criteria A |
---|
| Radiated Susceptibility | IEC/EN EN61000-4-3, Level 3, Criteria A |
---|
| Electrical Fast Transient | IEC/EN EN61000-4-4, Level 4, Criteria A |
---|
| Surge Immunity | IEC/EN EN61000-4-5, Level 4, Criteria A |
---|
| Transportation | ISTA Procedure 1E |
---|
POD | AMP Rating | 63A |
---|
| Connections | 4x ICE320 C19 16A/250V Sockets, 4x C13 10A/250V Sockets Power Input: Hard-Wired |
---|
Physical | Dimensions (mm) | 430 (w) x 630 (d) x 217 (h) |
---|
| Unit Weight | 74.5kg |
---|